Skip to main content

Correction: Experience with aortic arch inclusion technique using artificial blood vessel for type A aortic dissection: an application study

The Original Article was published on 08 April 2024

Correction: J Cardiothorac Surg 19, 189 (2024)

https://0-doi-org.brum.beds.ac.uk/10.1186/s13019-024-02741-8


Following the publication of the original article [1], Figs 2 and 3 were wrongly published; The figure published as Fig. 3 should actually be Fig. 2. Additionally, the figure originally intended to be presented as Figure 3, which contains vital imaging data pertinent to the study was missing. The figures 2 and 3 should have appeared as shown below.


Fig. 2
figure 1

Schematic diagram of modified sandwich method of aortic root reinforcement. (a) Semi-perspective diagram of aortic root. (b) The aortic root is sutured and reinforced and a spacer is added. (c) Use the “modified sandwich” method for full-thickness transmural suturing (pay attention to fully exposing the left and right coronal openings). (d) Top view of aortic root after reinforcement

Fig. 3
figure 2

Assessment of stent and thrombus status after TAAR. (a) The red arrow indicates that the thrombus in the false lumen of the aortic arch has been thrombosed after surgery, and the stent is in good shape. (b) The yellow arrow indicates that the thrombus in the false lumen of the descending aortic stent has been completely thrombosed after surgery, the stent is in good shape, and there is no endoleak. (c) The 3D reconstruction of the patient’s aortic CTA demonstrates the morphology of the stent

The original article has been corrected.

Reference

  1. Li Q, Li B, Xi S, et al. Experience with aortic arch inclusion technique using artificial blood vessel for type A aortic dissection: an application study. J Cardiothorac Surg. 2024;19:189. https://0-doi-org.brum.beds.ac.uk/10.1186/s13019-024-02741-8.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lei Liu.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, Q., Li, B., Xi, S. et al. Correction: Experience with aortic arch inclusion technique using artificial blood vessel for type A aortic dissection: an application study. J Cardiothorac Surg 19, 257 (2024). https://0-doi-org.brum.beds.ac.uk/10.1186/s13019-024-02774-z

Download citation

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s13019-024-02774-z