Skip to main content
  • Research article
  • Open access
  • Published:

Preserving the endothelium in saphenous vein graft with both conventional and no-touch preparation

Abstract

Background

Despite the inferior patency compared to arterial grafts, a saphenous vein graft (SVG) is widely used for coronary artery bypass grafting (CABG). A lower atherosclerosis rate and higher patency have been reported for SVG obtained via the no-touch technique (NT) than via conventional preparation (CV). Although CV-mediated endothelial dysfunction is implied, the precise mechanism underlying the higher patency with NT is poorly understood.

Methods

Human residual SVGs during CABG and SVG sections after autopsy were analyzed. The endothelial surface was observed using scanning electron microscopy (SEM) and blindly compared between CV and NT. The endothelial integrity was also analyzed with immunohistochemistry.

Results

Unexpectedly, the hyperfine structure on SEM was comparable between CV and NT before grafting, and microvillus, a characteristic of endothelium, was indistinguishable between them. Von Willebrand Factor, an endothelial marker, was equally detected throughout the vascular wall in both groups from residual and postmortem sections.

Conclusions

The morphological integrity of the endothelium was successfully preserved in SVG with CV, even at an ultrastructural level. Although its functionality remains to be addressed, other factors than the endothelium may be involved in the high patency obtained by NT. The present findings suggest that the characteristics of NT and surgical methodology should be reconsidered.

Peer Review reports

Background

Coronary artery bypass grafting (CABG) is a standard therapy for ischemic heart disease. Despite the inferior patency compared to arterial grafts, saphenous vein grafts (SVGs) are still widely transplanted for CABG due to their ease of manipulation [1,2,3,4]. Consequently, the long-term patency of SVG has been thoroughly investigated.

Conventional preparation (CV) of SVG, consisting of deprivation of surrounding tissues and distension, has been utilized for decades but is implied to be associated with atherogenesis and a poor patency rate [5,6,7,8]. Since the 1990s, the no-touch technique (NT), which preserves the outer tissues without distension, has been recognized as the superior alternative to CV due to its salutary effect. Accumulating evidence indicates that SVGs harvested with NT exhibit lower rates of atherosclerosis and higher patency than those harvested via CV [9,10,11,12]. Many cardiac surgeons have an intense interest in the higher patency of NT-SVG and its mechanism. However, the detailed mechanisms underlying these effects remain unclear.

Based on the studies comparing CV and NT, it is now broadly accepted that conventional distension injures the endothelium and medial architecture, inducing inflammation and intimal proliferation [5,6,7,8]. In CV group, an injury to vasa vasorum may also downregulate the endothelial function. Partial denudation of the endothelium was reproducibly detected after CV [6, 8, 13, 14]. Distension-mediated endothelial damage and denudation may therefore be significantly involved in vein graft failure after CV. However, the distending pressure varies among surgeons, and an early study reported that only higher pressures (≥700 mmHg) cause endothelial damage [15]. Whether or not this concept predominantly accounts for the difference in atherosclerosis and graft patency rates between CV and NT therefore remains unclear. Furthermore, atherosclerosis may be caused by multiple factors, and factors such as the surrounding tissue composition or secreted molecules may play a crucial role in protecting NT-harvested SVGs against atherosclerosis.

To clarify the predominant mechanism by which NT provides its salutary effect, we investigated the morphological features of the endothelium in the residual SVG harvested by CV or NT during CABG through scanning electron microscopy (SEM). We commissioned the scans and analyses from unbiased observers. Subsequently, the surprising results reported by them encouraged us to conduct further analyses regarding the endothelial integrity of the SVGs.

Methods

Surgical aspects

All saphenous veins were examined by echography before surgery to determine their size, morphology and functionality. Veins with any abnormalies, such as regurgitation, varix or varicose conditions, were excluded from graft candidates. CABG was performed in an on-pump or off-pump fashion by the surgeon’s choice. There were no marked differences in the handling of SVGs between on- and off-pump procedures. In on-pump cases, the surgical procedure was performed under cardiopulmonary bypass with moderate hypothermia (28 to 30 °C) and cardiac arrest with tepid blood cardioplegia. Vein grafts were mainly bypassed to the right coronary artery (RCA) and left circumflex artery (LCX), and the left anterior descending artery was reconstructed by the internal mammary artery. Vein grafts were anastomosed to the RCA or LCX, followed by perfusion with tepid blood cardioplegia (on-pump) or blood (off-pump) and anastomosis of the other side to the aorta.

SV harvesting techniques

  1. 1)

    CV group

The SV was exposed mainly from the lower leg by skipped longitudinal leg skin incisions, wherein the side branches were ligated. The vein was removed from the leg after dissection, connected to the cannula inserted into the femoral artery and dilated with arterial pressure for 10 min with blood mixed solution before the sewing of the anastomoses. The residual part of the vein was cut off from the central side (aortic side) after the anastomosis of the distal side to the RCA or LCX. In CV group, the vein was manually distended with blood mixed solution (30 ml blood, 3000 U of heparin sodium and 30 mg of papaverine hydrochloride) at < 300 mmHg. The adventitia was stripped off [16]. The harvested vein was stored in wet gauze at room temperature in an operating room. A few hours later, the stored vein was washed with PBS and fixed with specific buffer in our laboratory.

  1. 2)

    NT group

The SV was exposed via the same skin incisions as used for CV. The vein was isolated along with 5 mm of the surrounding fat tissue, and all visible side branches were ligated. After removal, the vein was connected to the cannula inserted into the femoral artery and dilated with arterial pressure for 10 min with blood mixed solution before the sewing of the anastomoses. The residual part of the vein was obtained as in the CV group. In the NT group, the vein was neither flushed nor distended manually. The adventitia was not removed. The harvested vein was stored and treated as in the CV group thereafter.

SVG pre-bypass samples (from patient no. 1- no. 5)

The residual SVG samples were obtained from Patient No. 1 via CV, Patient No. 2 via NT, and Patient No. 3- No. 5 via both CV and NT. The endothelial surface of SVGs from CV group (No. 1 and No. 3) and NT group (No. 2 and No. 3) was analyzed with SEM. The endothelial integrity of SVGs from CV group (No. 1, No. 4 and No. 5) and NT group (No. 2, No.4 and No. 5) was analyzed with immunohistochemistry.

SVG autopsy samples (from patient no. 6- no. 7)

  1. 1)

    Patient No. 6

The patient was a 75-year-old male. He had suffered acute myocardial infarction of the inferior wall. CAG revealed three-vessel disease, and he received CABG (on-pump, arrested heart) with LITA to LAD, SVGs to D1, 14PL, 4PD and 4PL. The CV technique was used to harvest SVGs. He ultimately died on day 8 after surgery due to low-output syndrome. The grafted SVG was harvested at the autopsy. Sample was prepared from the SVG to 14PL.

  1. 2)

    Patient No. 7

The patient was a 78-year-old male. He had suffered unstable angina. CAG revealed three-vessel disease, and he received off-pump CABG with RITA to LAD, LITA to 14PL, SVGs to D1, D2, 4PD and 4PL. The NT technique was used to harvest SVGs. He ultimately died on day 7 after surgery due to massive pulmonary embolism. The grafted SVG was harvested at the autopsy. Sample was prepared from the SVG to D1 and D2.

The patients’ characteristics are summarized below.

Patient No.

Age

Sex

On−/Off- pump

Preparation

Analysis

1

71

M

On

CV

SEM and immunohistochemistry

2

73

F

Off

NT

SEM and immunohistochemistry

3

77

M

On

CV and NT

SEM

4

78

M

Off

CV and NT

immunohistochemistry

5

68

M

On

CV and NT

immunohistochemistry

6

(autopsy)

75

M

On

CV

immunohistochemistry

7

(autopsy)

78

M

Off

NT

immunohistochemistry

SEM

The SEM analysis was conducted as described previously [17]. A few hours after resection, the SVG was fixed with 2% glutaraldehyde. We commissioned the scans and analyses from Hanaichi Ultrastructure Research Institute (Okazaki, Japan). The SVG section was washed, postfixed, dehydrated and examined by SEM (JSM-7500F; JEOL, Tokyo, Japan). We received the examination report from the company and also analyzed the images by ourselves.

Immunohistochemistry

Immunohistochemistry was conducted as described previously [18]. A few hours after resection, the SVG was fixed with 10% formalin overnight at room temperature and embedded in paraffin. Tissue sections (3 μm) were stained with anti-von Willebrand Factor antibody (#65707; Cell Signaling Technology, Beverly, MA, U.S.A.). All images were captured by a BZ-X710 microscope (Keyence, Osaka, Japan) and analyzed using the Image J software program (National Institutes of Health).

Results

The endothelial integrity of the residual SVG harvested by CV or NT before bypass-grafting was examined. Unexpectedly, the hyperfine structure on SEM was comparable between CV and NT before grafting (Fig. 1), and microvillus, a characteristic of endothelium, was observed in both cases, with a similar density and morphology (Fig. 1).

Fig. 1
figure 1

The inside of the residual SVG was observed with scanning microscopy. An unbiased observer reported no significant differences between the conventional (CV) and no-touch (NT) preparations. Representative images are shown in (a). The arrow indicates microvillus, a characteristic of endothelium. Scale bar, 1 μm. A summary is shown in (b). The average number of microvilli is indicated (n = 2).

Consistently, von Willebrand Factor (vWF), a representative marker of endothelial cell, was equally detected throughout the vascular wall in both groups (Fig. 2). There was no obvious defect or patch in the vWF signal throughout the entire luminal circumference of the CV group compared with the NT group. These results suggest that the morphological integrity of the endothelium was well maintained in the CV group even after pressure-mediated distension.

Fig. 2
figure 2

The endothelial integrity was assessed with immunohistochemistry in residual SVG. SVG was obtained with a conventional (CV) or no-touch (NT) approach during CABG. Representative stains of vWF (red) and DAPI (blue) are shown in (a). The demarcated area shows a higher magnification. Scale bar, 200 μm. A summary is shown in (b). The relative intensity of vWF normalized with that of DAPI is indicated (n = 3). Data are expressed as mean ± SEM.

Previous studies reported that high pressures induce endothelial inflammation after CV [5], suggesting that some of the endothelium may be lost in a later phase due to the accumulated damage. To address this issue, we collected autopsy sections of the SVG. The endothelium from 7 days after CV was compared with that from 8 days after NT. No marked differences were noted between them in the expression of vWF throughout the vascular wall (Fig. 3), suggesting that the endothelium was morphologically preserved after CV, even in the later phase.

Fig. 3
figure 3

The endothelial integrity was assessed with immunohistochemistry in SVG sections obtained after an autopsy. SVG was obtained with a conventional (CV) or no-touch (NT) approach. Representative stains of vWF (red) and DAPI (blue) are shown. Scale bar, 100 μm.

Discussion

In the present study, we clarified that the morphological integrity of the endothelium was successfully preserved in SVG with CV, even at an ultrastructural level. Although its functionality remains to be addressed, other factors than the endothelium may be involved in the high patency obtained by NT. The significance of the endothelium in mediating vascular homeostasis is generally well recognized, however, other factors are occasionally overlooked. Our study suggests that the characteristics of NT should be reconsidered, as this may innovatively stimulate the surgical methodology in the future.

One of the novel findings in this study is that the endothelial surface with microvillus was indistinguishable between CV and NT. To our knowledge, this is the first study comparing the hyperfine structure of the endothelial surface and microvillus between these procedures. Several previous studies used transmission electron microscopy (TEM) to observe SVG [19, 20]; our analysis using unbiased SEM is therefore unique.

Another novel point is our assessment of the endothelial integrity using postmortem sections. An early study with a large animal model noted that endothelial regeneration takes place as early as 7 days after denudation [16]. This finding thus suggests that even if endothelium is partially desquamated during CABG, the denuded lumina should become covered by newly generated endothelium within a short period of time. The endothelium we stained in the postmortem sections may have regenerated after denudation.

However, the present study possibly provides another hypothesis. Our data suggest that the endothelium after CV may be well preserved or only marginally damaged during CABG, showing a similar extent of damage to that after NT. Consequently, the remaining endothelium (rather than the regenerated tissue) may have been detected around the SVG wall in the postmortem sections.

There have been conflicting results regarding whether or not the endothelial integrity is preserved after pressure-mediated distension. In an earlier study involving the SEM analysis of the veins of monkey, distending pressure exceeding 700 mmHg induced morphological injury to the endothelium, while a lower pressure of 300–400 mmHg did not [15]. The endothelial morphology in veins subjected to this lower pressure was comparable to that in control veins lacking distension [15]. Conversely, studies with immunohistochemistry for CD31 using human SVGs demonstrated the partial loss of CD31 signaling after distension [6, 8]. Specifically, even after distension with a lower pressure of 100 mmHg, CD31 signaling was reduced by half, and the authors suggested that conventional distension significantly induced endothelial denudation [6].

While CD31 primarily localizes to the plasma membrane by exposing six extracellular domains on the cellular surface, vWF forms multimers in the endoplasmic reticulum and Golgi apparatus and is expressed in the cytosol before secretion [21,22,23]. As such, antigen of CD31 exposed on the endothelial surface may be vulnerable to distending pressure, thereby losing its reactivity to antibodies, whereas vWF in the cytosol may not be vulnerable. Although the hyperfine structure observed through SEM was comparable between the two groups in the present study, there might have been structural damages at a more hyperfine level on the endothelial surface in the CV group.

Since long-term patency is the ultimate goal of CABG, endothelial damage in the very acute phase may not be a critical for it. However, endothelial damage after distension is often discussed as if this is the predominant cause of poor patency in the CV group. The findings of the present study suggest the opposite due to the fact that there may be factors other than endothelium underlying the difference in the long-term patency between CV and NT.

Limitations of the study

Since the immunoreactivity in the postmortem section is generally reduced during long-term storage, our ability to collect useful sections for analyses was limited. We therefore examined only a single postmortem section in each group.

Conclusions

This study provides evidence that the endothelial hyperfine structure is well-preserved in SVGs harvested with CV. Other factors than the endothelium may play a pivotal role in protecting NT-harvested SVGs from atherosclerosis. Further investigations regarding the endothelial function and surrounding tissues will be required to elucidate the mechanism in detail.

Availability of data and materials

Not applicable.

Abbreviations

CABG:

Coronary artery bypass grafting

SVG:

Saphenous vein graft

CV:

Conventional preparation

NT:

No-touch technique

SEM:

Scanning electron microscopy

TEM:

Transmission electron microscopy

References

  1. Samano N, Dashwood M, Souza D. No-touch vein grafts and the destiny of venous revascularization in coronary artery bypass grafting-a 25(th) anniversary perspective. Ann Cardiothorac Surg. 2018;7(5):681–5 Epub 2018/12/07.

    Article  Google Scholar 

  2. Sabik JF 3rd, Blackstone EH, Gillinov AM, Banbury MK, Smedira NG, Lytle BW. Influence of patient characteristics and arterial grafts on freedom from coronary reoperation. J Thorac Cardiovasc Surg. 2006;131(1):90–8 Epub 2006/01/10.

    Article  Google Scholar 

  3. Zacharias A, Schwann TA, Riordan CJ, Durham SJ, Shah AS, Habib RH. Late results of conventional versus all-arterial revascularization based on internal thoracic and radial artery grafting. Ann Thorac Surg. 2009;87(1):19–26 e2. Epub 2008/12/23.

    Article  Google Scholar 

  4. Weiss AJ, Zhao S, Tian DH, Taggart DP, Yan TD. A meta-analysis comparing bilateral internal mammary artery with left internal mammary artery for coronary artery bypass grafting. Ann Cardiothorac Surg. 2013;2(4):390–400 Epub 2013/08/27.

    PubMed  PubMed Central  Google Scholar 

  5. Khaleel MS, Dorheim TA, Duryee MJ, Durbin HE Jr, Bussey WD, Garvin RP, et al. High-pressure distention of the saphenous vein during preparation results in increased markers of inflammation: a potential mechanism for graft failure. Ann Thorac Surg. 2012;93(2):552–8 Epub 2011/12/31.

    Article  Google Scholar 

  6. Stigler R, Steger C, Schachner T, Holfeld J, Edlinger M, Grimm M, et al. The impact of distension pressure on acute endothelial cell loss and neointimal proliferation in saphenous vein grafts. Eur J Cardiothorac Surg. 2012;42(4):e74–9 Epub 2012/08/22.

    Article  Google Scholar 

  7. Thatte HS, Khuri SF. The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency. Ann Thorac Surg. 2001;72(6):S2245–52 discussion S67–70. Epub 2002/01/16.

    Article  CAS  Google Scholar 

  8. Dashwood MR, Loesch A. Surgical damage of the saphenous vein and graft patency. J Thorac Cardiovasc Surg. 2007;133(1):274–5 Epub 2007/01/03.

    Article  Google Scholar 

  9. Samano N, Geijer H, Liden M, Fremes S, Bodin L, Souza D. The no-touch saphenous vein for coronary artery bypass grafting maintains a patency, after 16 years, comparable to the left internal thoracic artery: a randomized trial. J Thorac Cardiovasc Surg. 2015;150(4):880–8 Epub 2015/08/19.

    Article  Google Scholar 

  10. Johansson BL, Souza DS, Bodin L, Filbey D, Loesch A, Geijer H, et al. Slower progression of atherosclerosis in vein grafts harvested with ‘no touch’ technique compared with conventional harvesting technique in coronary artery bypass grafting: an angiographic and intravascular ultrasound study. Eur J Cardiothorac Surg. 2010;38(4):414–9 Epub 2010/04/07.

    Article  Google Scholar 

  11. Janiec M, Friberg O, Thelin S. Long-term clinical outcomes after coronary artery bypass grafting with pedicled saphenous vein grafts. J Cardiothorac Surg. 2018;13(1):122 Epub 2018/11/28.

    Article  Google Scholar 

  12. Deb S, Singh SK, de Souza D, Chu MWA, Whitlock R, Meyer SR, et al. SUPERIOR SVG: no touch saphenous harvesting to improve patency following coronary bypass grafting (a multi-Centre randomized control trial, NCT01047449). J Cardiothorac Surg. 2019;14(1):85 Epub 2019/05/03.

    Article  Google Scholar 

  13. Li FD, Eagle S, Brophy C, Hocking KM, Osgood M, Komalavilas P, et al. Pressure control during preparation of saphenous veins. JAMA Surg. 2014;149(7):655–62 Epub 2014/04/25.

    Article  Google Scholar 

  14. Dashwood MR, Savage K, Tsui JC, Dooley A, Shaw SG, Fernandez Alfonso MS, et al. Retaining perivascular tissue of human saphenous vein grafts protects against surgical and distension-induced damage and preserves endothelial nitric oxide synthase and nitric oxide synthase activity. J Thorac Cardiovasc Surg. 2009;138(2):334–40 Epub 2009/07/22.

    Article  CAS  Google Scholar 

  15. Bonchek LI. Prevention of endothelial damage during preparation of saphenous veins for bypass grafting. J Thorac Cardiovasc Surg. 1980;79(6):911–5 Epub 1980/06/01.

    Article  CAS  Google Scholar 

  16. Quist WC, Haudenschild CC, LoGerfo FW. Qualitative microscopy of implanted vein grafts. Effects of graft integrity on morphologic fate. J Thorac Cardiovasc Surg. 1992;103(4):671–7 Epub 1992/04/01.

    Article  CAS  Google Scholar 

  17. Ando H, Niki Y, Ito M, Akiyama K, Matsui MS, Yarosh DB, et al. Melanosomes are transferred from melanocytes to keratinocytes through the processes of packaging, release, uptake, and dispersion. J Invest Dermatol. 2012;132(4):1222–9 Epub 2011/12/23.

    Article  CAS  Google Scholar 

  18. Saito T, Uchiumi T, Yagi M, Amamoto R, Setoyama D, Matsushima Y, et al. Cardiomyocyte-specific loss of mitochondrial p32/C1qbp causes cardiomyopathy and activates stress responses. Cardiovasc Res. 2017;113(10):1173–85 Epub 2017/05/13.

    Article  CAS  Google Scholar 

  19. Verma S, Lovren F, Pan Y, Yanagawa B, Deb S, Karkhanis R, et al. Pedicled no-touch saphenous vein graft harvest limits vascular smooth muscle cell activation: the PATENT saphenous vein graft study. Eur J Cardiothorac Surg. 2014;45(4):717–25 Epub 2013/12/12.

    Article  Google Scholar 

  20. Dreifaldt M, Souza DS, Loesch A, Muddle JR, Karlsson MG, Filbey D, et al. The “no-touch” harvesting technique for vein grafts in coronary artery bypass surgery preserves an intact vasa vasorum. J Thorac Cardiovasc Surg. 2011;141(1):145–50 Epub 2010/04/13.

    Article  Google Scholar 

  21. Rakocevic J, Orlic D, Mitrovic-Ajtic O, Tomasevic M, Dobric M, Zlatic N, et al. Endothelial cell markers from clinician's perspective. Exp Mol Pathol. 2017;102(2):303–13 Epub 2017/02/14.

    Article  CAS  Google Scholar 

  22. Huang RH, Wang Y, Roth R, Yu X, Purvis AR, Heuser JE, et al. Assembly of Weibel-Palade body-like tubules from N-terminal domains of von Willebrand factor. Proc Natl Acad Sci U S A. 2008;105(2):482–7 Epub 2008/01/10.

    Article  CAS  Google Scholar 

  23. Purvis AR, Gross J, Dang LT, Huang RH, Kapadia M, Townsend RR, et al. Two Cys residues essential for von Willebrand factor multimer assembly in the Golgi. Proc Natl Acad Sci U S A. 2007;104(40):15647–52 Epub 2007/09/27.

    Article  CAS  Google Scholar 

Download references

Acknowledgments

We thank Yukari Hironaka for technical support and Dr. Brian Quinn for linguistic comments and help with the article.

Funding

This work was supported in part by Grants-in-Aids for Scientific Research (B) (19H03739 to K.H.), Scientific Research (C) (19 K09246 to R.S. and 18 K08761 to A.M.) and Young Scientists (19 K17601 to T.S.) from the Japan Society for the Promotion of Science; and grants from MSD Life Science Foundation, Public Interest Incorporated Foundation; Cardiovascular Research Fund; The Ichiro Kanehara Foundation for the Promotion of Medical Sciences and Medical care; The Mochida Memorial Foundation for Medical and Pharmaceutical Research; and The New Frontier Project of Yamaguchi University Graduate School of Medicine.

Author information

Authors and Affiliations

Authors

Contributions

TS designed the study, performed the experiments, analyzed data, interpreted results, provided project resources, and wrote the manuscript. HK, RS, YM, AM and KH performed surgeries. KH designed and supervised the study, interpreted results, provided project resources, and wrote the manuscript. All authors reviewed and commented on the manuscript. The author(s) read and approved the final manuscript.

Corresponding author

Correspondence to Kimikazu Hamano.

Ethics declarations

Ethics approval and consent to participate

This study was approved by Institutional Review Boards of Yamaguchi University Hospital (H2019–092) and followed the Declaration of Helsinki and the ethical standards of the responsible committee on human experimentation. All participants granted their informed consent.

Consent for publication

Not applicable.

Competing interests

Authors declared no conflicts of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Saito, T., Kurazumi, H., Suzuki, R. et al. Preserving the endothelium in saphenous vein graft with both conventional and no-touch preparation. J Cardiothorac Surg 15, 317 (2020). https://0-doi-org.brum.beds.ac.uk/10.1186/s13019-020-01352-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-020-01352-3

Keywords